flag_vietnam
logo-solutech
Hot News
tai-sao-nen-khu-trung-bang-clo2
Did you know: Why should chlorine disinfectant (Chlorine) be replaced with Chlorine Dioxide (ClO2)?
lam-mem-nuoc-ho-boi
Groundwater, other ingredients, calcium and manganese salts. Both substances cause total hardness. Just changing the pH value or temperature can cause precipitation. These visible precipitates (lime) precipitate on pipes, tank walls, chillers, fountains and steam generators. These precipitates can cause mechanical and thermal costs. Therefore, if you do not want to, it will cause unnecessary equipment failures!
quy-trinh-tu-dong
Optimizing and automating a line, such as reducing chemical consumption, treating wastewater in accordance with standards, quantifying and controlling the quantitative process correctly ... is always a problem. Urgency needs to be dealt with. If the customer is looking for a solution to this problem or wants systems with values and benefits that are far greater than the metering pumps, sensors, controllers or other individual devices, the main ProMinent is the right choice.

All You Need To Know About Back Pressure Valve

Back pressure valve/Relief valve is commonly used in the application of water treatment, industrial production, chemicals, ... to help protect the pump and help the chemical filling process take place correctly.
dhv-u-back-pressure-valves-solutech-2
APPLICATION OF BACK PRESSURE VALVE / RELIEF VALVE

Requirements:
• Stabilize chemical pump out flow when filling pressure changes
• Ensure the highest accuracy for the dosing process
• Protect the pump when the outlet pressure exceeds the pump's thrust capacity.

Operation conditions:
• Any change in the pressure at the filling point
• The metering pump is installed with the need for accurate and safe filling of the equipment.
• Chemical free of residues or pump suction end fitted with a filter
• In the following cases, a back-pressure valve can be installed:



Structure of Back pressure valve/ Relief valve:


How to use and install the Back pressure valve/Relief valve:

• Setting:
   o Threshold setting: 0.3 – 10 bar
   o Adjust screw to desired pressure
   o Tightening the fixed screw

• Error:
   o < 5bar, ±0.3bar
   o > 5bar, ± 0.5bar

• For example:

How to maintain and check the Back pressure valve / Relief valve error:

Error

Reason

How to handle

Membrance leak

Membrane tightening screw is not tight

Tighten the screws

Pressure drops below the set point

Valve seat/seal is faulty

Check valve seat/seal

Pressure exceeds the set point

Piston is stuck due to residue, garbage, etc. or installed in the wrong direction

Cleaning

Change into correct direction 

Leakage in adjusting screw

Membrance is torn

Replace new membrance

 More: ProMinent Back Pressure Valve / Relief Valve

Admin TH
Date Posted: 21/02/2020 18:02:00
APPLICATION
«   12  »

CUSTOMERS WE SERVE

nestle
lavie
heineken
1biasaigon
carlsberg
3abinbev
8nutifood
tanhiepphat
9vnm-new
bel
thmilk
17nsrp
nuiphaomining
schaeffler-logo
6dnphawaco
duongnhat
7pepsi
coca-cola
Hotline
Hotline