Groundwater, other ingredients, calcium and manganese salts. Both substances cause total hardness. Just changing the pH value or temperature can cause precipitation. These visible precipitates (lime) precipitate on pipes, tank walls, chillers, fountains and steam generators. These precipitates can cause mechanical and thermal costs. Therefore, if you do not want to, it will cause unnecessary equipment failures!
quy-trinh-tu-dong
Optimizing and automating a line, such as reducing chemical consumption, treating wastewater in accordance with standards, quantifying and controlling the quantitative process correctly ... is always a problem. Urgency needs to be dealt with. If the customer is looking for a solution to this problem or wants systems with values and benefits that are far greater than the metering pumps, sensors, controllers or other individual devices, the main ProMinent is the right choice.

Essentiality of pulsation dampers

Pulsation dampers are necessary devices for the efficiency of the liquid dosing system. To use them properly and effectively, it is necessary to understand the principle of operation and take note of installation and troubleshooting. At Solutech, we provide pulsation dampers that are best suited for the ProMinent metering pumps and also for the customer's dosing system.
bo-giam-chan-hidracar
Applications of Pulsation Dampers:

• Minimizing impulses at the ejector due to pump operation, increasing the durability of equipment and pipelines
• Stabilize pump flow
• Reduced suction & discharge pressure loss
• Eliminates cavitation when chemicals have the following properties:
   o High viscosity
   o Chemicals with gas
   o High volatility

Principle of operation:

Types of Pulsation Dampers:

Without membrance

With membrance

• Just an air tank
• The operating pressure of pulsation damper cannot be adjusted
• Some valves need to be added to regenerate the device during operation
• After a period of operation, the gas is dissolved into the solution, reducing the pulsation damper efficiency
• There is a membrane separating the gas and the solution
• Operating pressure can be adjusted based on charging pressure
• No need to add another valve system
• Stable performance

Installation diagram:

Structure of Pulsation dampers:

Notes when using and installing pulsation damper:
• Selecting the right pulsation damper for the pump
• The material is suitable for the chemical to be dosed
• The position of the pulsation damper must be closest to the point where the oscillation is generated
• Easy-to-operate location with isolating valve for handling and maintenance
• Pipes and equipment do not rest on the pulsation damper
• Damping valve must be fixed
• Ensure full accessories for back pressure valve, pressure relief valve & pressure gauge
• Use only nitrogen gas (no oxygen) to charge the pulsation damper!

Other notes:

+ After 500hr of work, check the air pressure in the pulsation damper
+ After a test run or when stopped for a long time
+ Check the tightness of connections and performance through pressure gauges

Common problem and how to fix it:
+ Pump creates a loud echo while working
+ No damping effect
   => Additional gas charging
   => Replace new membrane

See more: Pulsation Dampers Hidracar - No.1 damping solutions!
Admin TH
Date Posted: 21/02/2020 18:02:00
APPLICATION
«    12   »

CUSTOMERS WE SERVE

nestle
lavie
heineken
1biasaigon
carlsberg
3abinbev
8nutifood
tanhiepphat
9vnm-new
bel
thmilk
17nsrp
nuiphaomining
schaeffler-logo
6dnphawaco
duongnhat
7pepsi
coca-cola
Hotline
Hotline